Blogs here are based on Real Life Technical Problems faced by Experts in the Storage/Compute/Virtualization Domain. We hope to make life easy when you encounter these problems. People have faced them, you should not !!
Search This Blog
Tuesday, 18 December 2018
Thursday, 20 September 2018
CosBench on Red Hat Linux
What is Cosbench
COSBench is a benchmarking
tool to measure the performance of Cloud Object Storage services such as Amazon
S3, Opestack Swift, DELL EMC ECS, Google Cloud Storage etc. Intel developed
this tool.
Cosbench works on a
Controller and Driver design. Controller VM will utilize the Drivers VMs to
perform the IO on the Cloud Storage. So, there is can be only 1 VM that can be
configured as Controller and Driver VM. If you want to test much more stringent
tests, one controller VM and multiple drivers VMs can be utilized.
The detailed procedure for
installing and using Cosbench is available in the Download Package –
“COSBenchUserGuide.pdf”
So, you must be thinking if
everything is documented in User Guide, then what is the purpose of this
document !!! Hold On !!!
“The User Guide does not
cover the procedure for configuration on the RHEL OS, it only covers Ubuntu OS.
Well! If you follow that procedure for RHEL, it will fail !!!”
OK ! Let’s begin:
What is required?
·
A VM/machine that is
running RHEL with specifications defined in CosBench User Guide – “Reference
Hardware Configuration”.
·
Ask your RHEL guy to
make sure below packages are installed on the machine (very important):
o
Java Run Time
Environment 1.6 or later
o
Curl 7.22.0 or later
o
NC (netcat) package
o
Unzip package
·
Most importantly,
Download the latest CosBench Package from below link:
https://github.com/intel-cloud/cosbench/releases
Configuration on the Controller
·
FTP the CosBench
package on the RHEL Server, e.g. in the /cosbench.
·
Unzip 0.4.2.zip
·
Ln –s 0.4.2/
cos -------------------------- Creates a symbolic link to unzipped
files
·
Cd cos
·
Chmod +x .sh --------------------------
Sets the permissions to run scripts
Configuration Files
Cos/conf/controller.conf
This file will contain the
name and url of all the driver VM’s. Multiple entries if you are using multiple
VM’s. Entries goes like below:
[controller]
concurrency=1
drivers=3
log_level = INFO
log_file = log/system.log
archive_dir = archive
[driver1]
name=driver1
url=http://192.168.10.1:18088/driver
[driver2]
name=driver2
url=http://192.168.10.2:18088/driver
Note: If more driver VM’s,
add entries and change the name and url
Cos/cosbench-start.sh
This one is very important
for configuration on the RHEL servers. By default there is a line
(TOOL_PARAMS="-i 0"). This value does not applies to RHEL OS.
#-------------------------------
# COSBENCH STARTUP SCRIPT
#-------------------------------
SERVICE_NAME=$1
BOOT_LOG=log/$SERVICE_NAME-boot.log
OSGI_BUNDLES="$2"
OSGI_CONSOLE_PORT=$3
OSGI_CONFIG=conf/.$SERVICE_NAME
TOMCAT_CONFIG=conf/$SERVICE_NAME-tomcat-server.xml
TOOL="nc"
TOOL_PARAMS="-i 0" -----Delete this line
So edit this file and
delete this line.
Start the Controller
On the Controller VM:
1. Cd cos
2. ./start-all.sh
3. This should display that all the services are started
successfully.
4. Run the start-all script again if any error comes. Next
time, the service should start successfully.
Start the Drivers
On the Driver VM’s:
1. cd cos
2. ./start-driver.sh
3. This should display that all the services are started
successfully.
4. Run the start-all script again if any error comes. Next
time, the service should start successfully.
Run the Performance Test
Once the services are
started successfully on both Controller and Driver VM’s. You can launch the Web
Browser from any Machine that is in same LAN as that is the Controller VM. The
URL:
http://<controller-host>:19088/controller/index.html
Follow the ConBench User
Guide to do Configure the workloads
Wednesday, 11 July 2018
VNX Unified Power On and Power Off Procedure
VNX UNIFIED POWER OFF:
- Verify that there are no faults on the storage
- Before powering down the storage:
- Stop any replication
- Ensure Hosts are not accessing the data
- Connect to the Control Station using Putty. Login using nasadmin and su to root user
- Halt the Control Station and Data Movers using below command. Enter Yes when prompted to power off.
- # /nasmcd/sbin/nas_halt now
- This may take around 15-20 minutes max. Verify the Power LED on data movers and CS
Note: On the front of a successfully powered down DME, the enclosure amber fault LED is lit and the enclosure power LED is Not lit.
Only the networking indication LED(last LED in front from right) may be lit on a successfully powered down Control Station. All other LEDs on the front of the Control Station are off.
- Power-Off the Storage Processors by turning the SPS Switches to off position on both SPS. This should take around 5-10 minutes
- Remove the Power Cables
VNX UNIFIED POWER ON:
Note: Do not connect the power cables of all the components at once
- Turn on the SPS power switches to ON position. Wait for both SPs to boot 10-15 min.
- Connect the power cables of Data Movers to the PDU and wait for data movers to power up.
- Wait around 5 minutes to ensure data movers have booted up.
- Connect the Power cables for the Control Station. You may need to push the power button.
- Once all the components are up verify the health from Unisphere.
Monday, 4 June 2018
Initialize a Unity Storage without Network Connection
Problem Statement:
-----------------------
You have bought a new DELL EMC Unity Storage. Due to some policies, you cannot install Connection Utility or Command Line tool to initialize the Storage.
How will you proceed forward !!
Resolution:
-------------
" Unity Storage has Service IP address hard coded on the Service Port. However, you cannot directly access the IP address."
So How does it works ???
1. You need to first download the IPMI Tool from "support.emc.com" site. After downloading Install this. Default path of installation is C:\IPMItool
2. Have the Service IP Information noted down:
SP A Service IP: 128.221.1.252
SP B Service IP: 128.221.1.253
3. Connect to SP A or SP B Service Port Using the LAN Cable to your laptop.
Service Port is the port on left bottom of below pic marked with a wrench symbol
4. Assign below IP address to the Laptop
Laptop IP Address: 128.221.1.250 / Subnet: 255.255.255.0
5. Open Command Prompt and change the default location to C:\IPMItool. Run below command:
ipmitool.exe -I lanplus -C 3 -U console -P <passwordbg> -H
<host> sol activate
Password is the Serial No of Unity Storage. You can find it on PSNT Tag on back or front side of storage physically.
Host is the IP address of Service SP A or SP B mentioned above already.
6. Once you run the above command, you will see the SP Login Prompt. Enter the default credentials.
One fun exercise here... Username is admin or service. You need to find out what the default password is !!!
7. Run below command to configure the IP address and Hostname for your Unity Storage:
svc_initial_config –a –f <hostname> -n “<IP Address>
<Netmask> <Gateway>”
Hostname is the hostname you want to confgure
IP address is the Mgmt IP address
Netmask is Subnet Mask
Gateway is default gateway
After the command succeeds. You need to connect to the Management port of SP and ping the configured IP address.
All the best !
Monday, 29 January 2018
DELL EMC Unity Sizer
Unity Sizer is your one stop destination for all the best practices for sizing configuration for Unity Storage.
You must have DELL EMC Support Account to access the tool.
Here you go !!
https://midrangesizer.emc.com/
Thanks!
You must have DELL EMC Support Account to access the tool.
Here you go !!
https://midrangesizer.emc.com/
Thanks!
Thursday, 4 January 2018
Add a meta device with soft partitions in Main Mirror (Solaris SVM)
Title:
Adding a meta device with soft partitions to Main Mirror in
Solaris SVM.
Scenario:
Storage LUN (c4t60000970000297000217533030373445d0s0) is under control
of metadevice d888 which is having two soft partitions d890 and d891. Customer
want to mirror this LUN to another LUN from different storage. For mirroring,
we need to add both the LUNs under a Main Mirror in SVM. However, the source
LUN is having soft partitions so we cannot simply add this LUN under main
mirror.
Resolution:
1. Remove the Soft
partitions from the meta device and note down the starting and ending block
details.
2. Add the Meta
Device under the control of Main Mirror.
3. Create the Soft
partitions on the Main Mirror.
4. Create Meta Device
on new LUN and add it under Main Mirror.
Note: This process
involves downtime because the mount points needs to be unmounted which are
using the soft partitions. Before initiating with the procedure, take latest
backup of these mount points.
Procedure:
1. Note down the
MetaDevice and soft partition details from the output of metastat –p command.
d888 1 1
c4t60000970000297000217533030373445d0s0
d891 -p d888 -o 104861504 -b
102760448
d890 -p d888 -o 3872 -b 104857600
Here d888 is the Meta Device and d890 and d891 are the soft
partitions and they are mounted on the server as below:
/dev/md/dsk/d890
49G 1.0G 48G
3% /test1
/dev/md/dsk/d891
48G 49M 48G
1% /test2
2. Unmount the mount
points
3. Clear the Soft
Partitions
root@test # metaclear d890
d890: Soft Partition is cleared
root@test # metaclear d891
d891: Soft Partition is cleared
4. Add the metadevice
d888 to Main Mirror d880
root@test # metainit d880 -m d888
d880: Mirror is setup
5. Verify the Main
Mirror Properties of d880
root@gnnems25 # metastat d880
d880: Mirror
Submirror 0: d888
State: Okay
Pass: 1
Read
option: roundrobin (default)
Write
option: parallel (default)
Size:
209710080 blocks (99 GB)
d888: Submirror of d880
State:
Okay
Size:
209710080 blocks (99 GB)
Stripe
0:
Device
Start Block Dbase State Reloc
Hot Spare
c4t60000970000297000217533030373445d0s0
0
No
Okay Yes
6. Create the soft
partitions on the Main Mirror referring the output of metastat –p in step 1.
root@test # metainit d891 -p d880 -o
104861504 -b 102760448
d891: Soft Partition is setup
root@test # metainit d890 -p d880 -o
3872 -b 104857600
d890: Soft Partition is setup
7. Mount the Soft
partitions to verify the data integrity.
root@test # mount /dev/md/dsk/d890
/test1
root@test # mount /dev/md/dsk/d891
/test2
Verify the Size details in df –h, which will be same as
earlier and data will be accessible.
/dev/md/dsk/d890
49G 1.0G 48G 3%
/test1
/dev/md/dsk/d891
48G 49M
48G 1% /test2
8. Create MetaDevice
on the new LUN and add the new MetaDevice under main mirror d880 using
standard procedure.
Labels:
can i delete soft partition,
create,
how to add a meta device,
main mirror,
Meta device,
metadevice,
mirror,
partition,
soft,
soft partitions,
solaris,
Solaris Volume Manager,
SVM
Subscribe to: